Direct R&D · Direct production · Direct supportinfo@oromee.com
BA112 Wide-range Dual-channel TDS & Temperature ASIC
Sensor Interface ASICsCurrent model

BA112

Wide-range Dual-channel TDS & Temperature ASIC | TDS sensor IC

Wide-range dual-channel TDS and temperature ASIC with probe diagnostics, two-point calibration and automatic BURST mode.

Original manufacturer · Factory-direct supply

Questions go straight to the source

Ask about parameters, interfaces, calibration, versions, customization or volume supply. The answer does not need to pass through layers of resellers.

  • In-house R&DOptics, sensor-interface electronics, algorithms, firmware and mechanical integration are developed as one product system.
  • Production capabilityFrom prototype and pilot build to assembly, functional testing and volume delivery, production follows the product team’s technical definition.
  • Quality traceabilityModel, specification, firmware or hardware version and test requirements remain connected, reducing ambiguity between sales claims and delivered goods.
Talk directly to the manufacturer →
Overview

Why this product

Wide-range dual-channel TDS and temperature ASIC with probe diagnostics, two-point calibration and automatic BURST mode.

A newer wide-range dual-channel TDS ASIC with probe-status diagnostics, bipolar drive and application calibration commands. It is designed for appliances that need both broader range and better diagnostic coverage.

BA112 integrates two TDS channels, two temperature channels, bipolar probe drive, suspended-probe and NTC fault detection, two-point calibration, UART control and automatic BURST operation for wide-range appliance designs.

  • Two TDS and two temperature channels
  • 0–10000 ppm wide-range measurement
  • Suspended-probe and NTC open/short diagnostics
  • Bipolar drive and two-point calibration
  • UART commands plus automatic BURST mode
Verified technical detail

Information to provide for selection · Calibration, validation and maintenance

Wide-range dual-channel TDS and temperature ASIC with probe diagnostics, two-point calibration and automatic BURST mode.

01

Overview

A newer wide-range dual-channel TDS ASIC with probe-status diagnostics, bipolar drive and application calibration commands. It is designed for appliances that need both broader range and better diagnostic coverage.

02

Interface / Supply

UART, 9600 bps; automatic BURST mode · 3.3 V or 5 V; ripple <20 mV; current <3 mA

03

Measurement Range / Accuracy

0–10000 ppm TDS, dual channel · <2% F.S. at 0–2000 ppm; <5% F.S. at 2000–10000 ppm

04

Installation and commissioning

Use identical probes on both channels and separate them by at least 0.5 m in the same water.

Verified technical detail

Engineering and integration

The official Chinese document is currently shared by every language version.

Engineering and integration

  • 01

    0–10000 ppm range: below 2% F.S. from 0–2000 ppm and below 5% F.S. from 2000–10000 ppm.

  • 01

    Two TDS and two temperature channels; -10–100 °C with ±0.5 °C reference accuracy.

  • 01

    3.3 V or 5 V supply, below 3 mA; UART 9600 bps in SOP14.

  • 01

    Detects suspended probes and NTC open/short conditions; supports two-point calibration and automatic BURST operation.

Installation and commissioning

  • Use identical probes on both channels and separate them by at least 0.5 m in the same water.

  • Use the official calibration commands when integrating probes other than the matched BA01 probe.

  • Verify supply and digital levels for the chosen 3.3 V or 5 V system.

Applications

Typical applications

Use the product as part of a complete measurement workflow, not as an isolated component. Confirm the water matrix, target range and decision that the data must support.

04

Drinking Water & Purification

Integrated TDS and conductivity components for dispensers, purifiers, filter-life estimation and quality indication.

05

Industrial Process Water

Digital sensors and embedded ASICs for equipment builders, automation systems and water-intensive production.

06

Smart Appliances

Small-footprint sensing electronics for connected water devices, pet appliances and intelligent home products.

Typical applications are reference cases, not capability limits.

The applications above are common examples. If this measurement principle may solve a different problem in your field, we welcome a feasibility discussion.

Propose a new application →
Technology

From selection to reliable data

  1. 01

    Define the measurement objective and expected range.

  2. 02

    Match the sensor, probe or analyzer to the real sample matrix.

  3. 03

    Complete mechanical, electrical and communication integration.

  4. 04

    Validate results with reference samples before routine operation.

Engineered for dependable integration

Integration and installation checklist

  • Target parameters and expected concentration range
  • Water matrix, fouling risk and installation method
  • Communication interface and sampling frequency
  • Calibration, validation and maintenance strategy
  • Information to provide for selection: BA112 · Sensor Interface ASICs

Calibration, validation and maintenance

Validate the complete system with representative samples. Record the reference method, temperature and installation conditions. Recheck after cleaning, replacement or process changes, and define a maintenance interval from actual fouling rather than a fixed assumption.

FAQ

Frequently asked questions

Is this product ready to use in every water matrix?

The product platform is defined, but range, calibration and installation must still be confirmed against the actual water matrix and project objective.

What should be checked before integration?

Confirm power, interface, cable length, enclosure, sampling frequency, probe position and the host system data format.

How should measurement quality be verified?

Compare representative samples with an agreed reference method and document the acceptance criteria before commissioning.

Can datasheets, protocol information and engineering support be supplied?

Yes. Ask for the current ordering specification and describe your application so the correct materials can be supplied.

BA112

Request a Quote

Tell us your target parameters, water matrix, interface and annual volume. Our engineering team will recommend a practical configuration.

Related Products

Related Products

BA111 Single-channel TDS Sensor Interface ASIC
Sensor Interface ASICs

BA111

Single-channel TDS Sensor Interface ASIC

Highly integrated TDS and water-temperature measurement ASIC with bipolar probe drive and UART control.

Learn More
BA121 Conductivity Sensor Interface ASIC
Sensor Interface ASICs

BA121

Conductivity Sensor Interface ASIC

Single-channel conductivity and water-temperature ASIC for compact smart-water products.

Learn More
BA121S Low-range Conductivity Interface ASIC
Sensor Interface ASICs

BA121S

Low-range Conductivity Interface ASIC

High-resolution low-conductivity measurement ASIC for purified-water and precision applications.

Learn More
Built for integration

Discuss your application

Tell us your target parameters, water matrix, interface and annual volume. Our engineering team will recommend a practical configuration.

Request a Quote