Direct R&D · Direct production · Direct supportinfo@oromee.com
BA234 Multi-parameter Sensor Interface ASIC
Sensor Interface ASICsCurrent model

BA234

Multi-parameter Sensor Interface ASIC | TDS sensor IC

Single-channel, two-probe interface ASIC with NTC compensation and UART digital output.

Original manufacturer · Factory-direct supply

Questions go straight to the source

Ask about parameters, interfaces, calibration, versions, customization or volume supply. The answer does not need to pass through layers of resellers.

  • In-house R&DOptics, sensor-interface electronics, algorithms, firmware and mechanical integration are developed as one product system.
  • Production capabilityFrom prototype and pilot build to assembly, functional testing and volume delivery, production follows the product team’s technical definition.
  • Quality traceabilityModel, specification, firmware or hardware version and test requirements remain connected, reducing ambiguity between sales claims and delivered goods.
Talk directly to the manufacturer →
Overview

Why this product

Single-channel, two-probe interface ASIC with NTC compensation and UART digital output.

A configurable conductivity signal-processing ASIC that integrates probe excitation, acquisition, amplification, filtering, temperature compensation and digital output. It is intended for designs that need more flexibility than a fixed-range appliance ASIC.

Single-channel, two-probe interface ASIC with NTC compensation and UART digital output.

  • Single-channel two-probe measurement
  • Automatic NTC temperature compensation
  • Bipolar pulse excitation
  • Simple control commands
  • UART digital output at 9600 bps
Verified technical detail

Information to provide for selection · Calibration, validation and maintenance

Single-channel, two-probe interface ASIC with NTC compensation and UART digital output.

01

Overview

A configurable conductivity signal-processing ASIC that integrates probe excitation, acquisition, amplification, filtering, temperature compensation and digital output. It is intended for designs that need more flexibility than a fixed-range appliance ASIC.

02

Interface / Supply

UART, 9600 bps · 3.3 V ±0.3 V

03

Measurement Range / Accuracy

Probe and parameter dependent · Application calibration dependent

04

Installation and commissioning

Define the electrode material, cell constant and intended conductivity range before configuring the analog path.

Verified technical detail

Engineering and integration

The official Chinese document is currently shared by every language version.

Engineering and integration

  • 01

    Single-channel, two-probe measurement with bipolar pulse excitation.

  • 01

    3.3 V ±0.3 V supply, approximately 1 mA operating current and UART 9600 bps.

  • 01

    Automatic NTC temperature compensation and digital control ports.

  • 01

    QFN32 package; the achievable range and accuracy depend on probe and calibration configuration.

Installation and commissioning

  • Define the electrode material, cell constant and intended conductivity range before configuring the analog path.

  • Observe low-leakage PCB layout around analog inputs.

  • Build a multipoint calibration using the final probe and target water matrix.

Applications

Typical applications

Use the product as part of a complete measurement workflow, not as an isolated component. Confirm the water matrix, target range and decision that the data must support.

04

Drinking Water & Purification

Integrated TDS and conductivity components for dispensers, purifiers, filter-life estimation and quality indication.

05

Industrial Process Water

Digital sensors and embedded ASICs for equipment builders, automation systems and water-intensive production.

06

Smart Appliances

Small-footprint sensing electronics for connected water devices, pet appliances and intelligent home products.

Typical applications are reference cases, not capability limits.

The applications above are common examples. If this measurement principle may solve a different problem in your field, we welcome a feasibility discussion.

Propose a new application →
Technology

From selection to reliable data

  1. 01

    Define the measurement objective and expected range.

  2. 02

    Match the sensor, probe or analyzer to the real sample matrix.

  3. 03

    Complete mechanical, electrical and communication integration.

  4. 04

    Validate results with reference samples before routine operation.

Engineered for dependable integration

Integration and installation checklist

  • Target parameters and expected concentration range
  • Water matrix, fouling risk and installation method
  • Communication interface and sampling frequency
  • Calibration, validation and maintenance strategy
  • Information to provide for selection: BA234 · Sensor Interface ASICs

Calibration, validation and maintenance

Validate the complete system with representative samples. Record the reference method, temperature and installation conditions. Recheck after cleaning, replacement or process changes, and define a maintenance interval from actual fouling rather than a fixed assumption.

FAQ

Frequently asked questions

Is this product ready to use in every water matrix?

The product platform is defined, but range, calibration and installation must still be confirmed against the actual water matrix and project objective.

What should be checked before integration?

Confirm power, interface, cable length, enclosure, sampling frequency, probe position and the host system data format.

How should measurement quality be verified?

Compare representative samples with an agreed reference method and document the acceptance criteria before commissioning.

Can datasheets, protocol information and engineering support be supplied?

Yes. Ask for the current ordering specification and describe your application so the correct materials can be supplied.

BA234

Request a Quote

Tell us your target parameters, water matrix, interface and annual volume. Our engineering team will recommend a practical configuration.

Related Products

Related Products

BA111 Single-channel TDS Sensor Interface ASIC
Sensor Interface ASICs

BA111

Single-channel TDS Sensor Interface ASIC

Highly integrated TDS and water-temperature measurement ASIC with bipolar probe drive and UART control.

Learn More
BA121 Conductivity Sensor Interface ASIC
Sensor Interface ASICs

BA121

Conductivity Sensor Interface ASIC

Single-channel conductivity and water-temperature ASIC for compact smart-water products.

Learn More
BA121S Low-range Conductivity Interface ASIC
Sensor Interface ASICs

BA121S

Low-range Conductivity Interface ASIC

High-resolution low-conductivity measurement ASIC for purified-water and precision applications.

Learn More
Built for integration

Discuss your application

Tell us your target parameters, water matrix, interface and annual volume. Our engineering team will recommend a practical configuration.

Request a Quote