Direct R&D · Direct production · Direct supportinfo@oromee.com
BA311 Miniature TDS Sensor Interface ASIC
Sensor Interface ASICsCurrent model

BA311

Miniature TDS Sensor Interface ASIC | TDS sensor IC

Compact automatic TDS measurement ASIC in SOT23-6 for space-constrained smart-water products.

Original manufacturer · Factory-direct supply

Questions go straight to the source

Ask about parameters, interfaces, calibration, versions, customization or volume supply. The answer does not need to pass through layers of resellers.

  • In-house R&DOptics, sensor-interface electronics, algorithms, firmware and mechanical integration are developed as one product system.
  • Production capabilityFrom prototype and pilot build to assembly, functional testing and volume delivery, production follows the product team’s technical definition.
  • Quality traceabilityModel, specification, firmware or hardware version and test requirements remain connected, reducing ambiguity between sales claims and delivered goods.
Talk directly to the manufacturer →
Overview

Why this product

Compact automatic TDS measurement ASIC in SOT23-6 for space-constrained smart-water products.

A very small automatic TDS ASIC for cost- and space-sensitive products. It measures periodically and transmits the result from a Tx-only output, reducing MCU software and package footprint.

Compact automatic TDS measurement ASIC in SOT23-6 for space-constrained smart-water products.

  • 0–3000 ppm TDS measurement
  • Automatic 300 ms measurement cycle
  • 3–5 V wide-voltage supply
  • Bipolar drive reduces probe polarization
  • BURST Tx data output and SOT23-6 package
Verified technical detail

Information to provide for selection · Calibration, validation and maintenance

Compact automatic TDS measurement ASIC in SOT23-6 for space-constrained smart-water products.

01

Overview

A very small automatic TDS ASIC for cost- and space-sensitive products. It measures periodically and transmits the result from a Tx-only output, reducing MCU software and package footprint.

02

Interface / Supply

BURST data output (Tx) · 3–5 V

03

Measurement Range / Accuracy

0–3000 ppm TDS · < 2% F.S.

04

Installation and commissioning

Design the host to receive the periodic Tx-only data stream; there is no command Rx pin.

Verified technical detail

Engineering and integration

The official Chinese document is currently shared by every language version.

Engineering and integration

  • 01

    0–3000 ppm TDS with error below 2% F.S.

  • 01

    3–5 V wide supply; approximately 1.6 mA average at 3.3 V in clean water.

  • 01

    Automatic result output every 300 ms through UART Tx-only, 9600 bps.

  • 01

    SOT23-6 package and -40 to +85 °C operating temperature grade.

Installation and commissioning

  • Design the host to receive the periodic Tx-only data stream; there is no command Rx pin.

  • Account for supply-referenced digital output level when connecting the MCU.

  • Calibrate with the final probe and mechanical arrangement because immersion geometry affects the scale factor.

Applications

Typical applications

Use the product as part of a complete measurement workflow, not as an isolated component. Confirm the water matrix, target range and decision that the data must support.

04

Drinking Water & Purification

Integrated TDS and conductivity components for dispensers, purifiers, filter-life estimation and quality indication.

05

Industrial Process Water

Digital sensors and embedded ASICs for equipment builders, automation systems and water-intensive production.

06

Smart Appliances

Small-footprint sensing electronics for connected water devices, pet appliances and intelligent home products.

Typical applications are reference cases, not capability limits.

The applications above are common examples. If this measurement principle may solve a different problem in your field, we welcome a feasibility discussion.

Propose a new application →
Technology

From selection to reliable data

  1. 01

    Define the measurement objective and expected range.

  2. 02

    Match the sensor, probe or analyzer to the real sample matrix.

  3. 03

    Complete mechanical, electrical and communication integration.

  4. 04

    Validate results with reference samples before routine operation.

Engineered for dependable integration

Integration and installation checklist

  • Target parameters and expected concentration range
  • Water matrix, fouling risk and installation method
  • Communication interface and sampling frequency
  • Calibration, validation and maintenance strategy
  • Information to provide for selection: BA311 · Sensor Interface ASICs

Calibration, validation and maintenance

Validate the complete system with representative samples. Record the reference method, temperature and installation conditions. Recheck after cleaning, replacement or process changes, and define a maintenance interval from actual fouling rather than a fixed assumption.

FAQ

Frequently asked questions

Is this product ready to use in every water matrix?

The product platform is defined, but range, calibration and installation must still be confirmed against the actual water matrix and project objective.

What should be checked before integration?

Confirm power, interface, cable length, enclosure, sampling frequency, probe position and the host system data format.

How should measurement quality be verified?

Compare representative samples with an agreed reference method and document the acceptance criteria before commissioning.

Can datasheets, protocol information and engineering support be supplied?

Yes. Ask for the current ordering specification and describe your application so the correct materials can be supplied.

BA311

Request a Quote

Tell us your target parameters, water matrix, interface and annual volume. Our engineering team will recommend a practical configuration.

Related Products

Related Products

BA111 Single-channel TDS Sensor Interface ASIC
Sensor Interface ASICs

BA111

Single-channel TDS Sensor Interface ASIC

Highly integrated TDS and water-temperature measurement ASIC with bipolar probe drive and UART control.

Learn More
BA121 Conductivity Sensor Interface ASIC
Sensor Interface ASICs

BA121

Conductivity Sensor Interface ASIC

Single-channel conductivity and water-temperature ASIC for compact smart-water products.

Learn More
BA121S Low-range Conductivity Interface ASIC
Sensor Interface ASICs

BA121S

Low-range Conductivity Interface ASIC

High-resolution low-conductivity measurement ASIC for purified-water and precision applications.

Learn More
Built for integration

Discuss your application

Tell us your target parameters, water matrix, interface and annual volume. Our engineering team will recommend a practical configuration.

Request a Quote