Direct R&D · Direct production · Direct supportinfo@oromee.com
5-in-1 EC/TDS Industrial 5-in-1 Conductivity Sensor
Water Quality SensorsCurrent model

5-in-1 EC/TDS

Industrial 5-in-1 Conductivity Sensor | water quality sensor

Integrated industrial probe for conductivity, TDS, salinity, specific gravity and temperature with titanium electrodes.

Key Specifications
Original manufacturer · Factory-direct supply

Questions go straight to the source

Ask about parameters, interfaces, calibration, versions, customization or volume supply. The answer does not need to pass through layers of resellers.

  • In-house R&DOptics, sensor-interface electronics, algorithms, firmware and mechanical integration are developed as one product system.
  • Production capabilityFrom prototype and pilot build to assembly, functional testing and volume delivery, production follows the product team’s technical definition.
  • Quality traceabilityModel, specification, firmware or hardware version and test requirements remain connected, reducing ambiguity between sales claims and delivered goods.
Talk directly to the manufacturer →
Overview

Why this product

Integrated industrial probe for conductivity, TDS, salinity, specific gravity and temperature with titanium electrodes.

An integrated industrial probe that combines conductivity, TDS, salinity, specific gravity and temperature. Titanium electrodes, temperature compensation and digital communication reduce the number of separate probes required by a monitoring system.

One probe acquires five water-quality indicators, reducing wiring and mechanical complexity. A polypropylene body, pure-titanium electrodes, temperature compensation and RS485 communication support continuous process, treatment, laboratory and aquaculture monitoring.

  • EC, TDS, salinity, specific gravity and temperature
  • Pure-titanium electrodes for corrosion resistance
  • Polypropylene body for continuous water contact
  • Temperature compensation and private RS485 protocol
  • G3/4 connection and optional touch controller
Verified technical detail

Information to provide for selection · Calibration, validation and maintenance

Integrated industrial probe for conductivity, TDS, salinity, specific gravity and temperature with titanium electrodes.

01

Overview

An integrated industrial probe that combines conductivity, TDS, salinity, specific gravity and temperature. Titanium electrodes, temperature compensation and digital communication reduce the number of separate probes required by a monitoring system.

02

Interface / Supply

RS485 private protocol; optional color touch controller · DC 6–16 V; 12 V typical; sensor 0.1 W

03

Measurement Range / Accuracy

EC 0–100 mS/cm; TDS 0–20000 ppm; salinity 0–5%; specific gravity 1–1.06; hardness to 1000 ppm; 0–60 °C · EC/TDS/salinity <2% F.S.; temperature ±2% F.S.

04

Installation and commissioning

Choose the electrode configuration and cell constant for the required conductivity range.

Verified technical detail

Engineering and integration

The official Chinese document is currently shared by every language version.

Engineering and integration

  • 01

    Five indicators from one wetted probe: EC, TDS, salinity, specific gravity and temperature.

  • 01

    Pure-titanium electrodes and polypropylene wetted structure support corrosion-resistant continuous use.

  • 01

    RS485 digital communication and an optional color touch controller simplify system integration.

  • 01

    G3/4 process connection and up to 1.5 MPa line pressure support in-line installations.

Installation and commissioning

  • Choose the electrode configuration and cell constant for the required conductivity range.

  • Install where the electrodes remain wetted and free of trapped bubbles or sediment pockets.

  • Calibrate with certified conductivity standards and configure the intended TDS conversion factor.

Applications

Typical applications

Use the product as part of a complete measurement workflow, not as an isolated component. Confirm the water matrix, target range and decision that the data must support.

01

Wastewater Treatment

Continuous, high-density water data for process optimization, inlet/outlet comparison and early anomaly detection.

02

Surface Water Monitoring

Compact, reagent-free sensing for rivers, lakes, reservoirs and distributed environmental networks.

05

Industrial Process Water

Digital sensors and embedded ASICs for equipment builders, automation systems and water-intensive production.

Typical applications are reference cases, not capability limits.

The applications above are common examples. If this measurement principle may solve a different problem in your field, we welcome a feasibility discussion.

Propose a new application →
Technology

From selection to reliable data

  1. 01

    Define the measurement objective and expected range.

  2. 02

    Match the sensor, probe or analyzer to the real sample matrix.

  3. 03

    Complete mechanical, electrical and communication integration.

  4. 04

    Validate results with reference samples before routine operation.

Engineered for dependable integration

Integration and installation checklist

  • Target parameters and expected concentration range
  • Water matrix, fouling risk and installation method
  • Communication interface and sampling frequency
  • Calibration, validation and maintenance strategy
  • Information to provide for selection: 5-in-1 EC/TDS · Water Quality Sensors

Calibration, validation and maintenance

Validate the complete system with representative samples. Record the reference method, temperature and installation conditions. Recheck after cleaning, replacement or process changes, and define a maintenance interval from actual fouling rather than a fixed assumption.

FAQ

Frequently asked questions

Is this product ready to use in every water matrix?

The product platform is defined, but range, calibration and installation must still be confirmed against the actual water matrix and project objective.

What should be checked before integration?

Confirm power, interface, cable length, enclosure, sampling frequency, probe position and the host system data format.

How should measurement quality be verified?

Compare representative samples with an agreed reference method and document the acceptance criteria before commissioning.

Can datasheets, protocol information and engineering support be supplied?

Yes. Ask for the current ordering specification and describe your application so the correct materials can be supplied.

5-in-1 EC/TDS

Request a Quote

Tell us your target parameters, water matrix, interface and annual volume. Our engineering team will recommend a practical configuration.

Related Products

Related Products

NSDD6 Industrial Multispectral Water Quality Sensor
Water Quality Sensors

NSDD6

Industrial Multispectral Water Quality Sensor

Self-cleaning, reagent-free multispectral sensor for continuous organic pollution, turbidity, color and temperature monitoring.

Learn More
NSDD-Lite3 Compact Multispectral Water Quality Sensor
Water Quality Sensors

NSDD-Lite3

Compact Multispectral Water Quality Sensor

Compact reagent-free online sensor for TOC, COD, UV254 and temperature in commercial and high-purity water systems.

Learn More
Built for integration

Discuss your application

Tell us your target parameters, water matrix, interface and annual volume. Our engineering team will recommend a practical configuration.

Request a Quote